4M series solenoid valve
Keyword:
Air source treatment
Control component
Executing component
Angle seat valve
Environmental protection industry
Valve industry
Auxiliary components
Custom components
Symbol
Product Features
1. Internal pilot-operated structure;
2. Sliding plunger structure, good sealing, sensitive response;
3. Double-head two-position solenoid valve with memory function;
4. The inner hole is processed with special technology, with low friction resistance, low starting air pressure, and long service life;
5. No need for oil lubrication;
6. Side-plate mounting, can be directly connected with the actuator;
7. Equipped with a manual device, which is convenient for installation and debugging;
8. A variety of standard voltage levels are available.
Specifications
[Note 1] Pipe connection types include G and NPT threads.
[Note 2] If oil lubrication is used, it should not be stopped midway. ISO VG32 or equivalent oil is recommended.
[Note 3] The maximum operating frequency is under no-load conditions.
[Note 4] The effective cross-sectional area and Cv value are calculated based on the measured flow data.
Electrical Performance Parameters
| Item | 4M110 4M120 | 4M210 4M220 4M310 4M320 | ||||||||||||||||
| Standard Voltage | AC220V | AC110V | AC24V | DC24V | DC12V | AC220V | AC110V | AC24V | DC24V | DC12V | ||||||||
| Operating Voltage Range | AC: ±15% DC: ±10% | |||||||||||||||||
| Power Consumption | 3.5VA | 3.5VA | 4.0VA | 2.8W | 2.5W | 45VA | 4.5VA | 5.0VA | 3.0W | 2.5W | ||||||||
| Protection Level | IP65 (DIN40050) | |||||||||||||||||
| Insulation Class | Class B | |||||||||||||||||
| Wiring Type | DIN socket type, lead-out type | |||||||||||||||||
| Excitation Time | Less than 0.05 seconds | |||||||||||||||||
Finished Product Ordering Code
External Specifications